ACME Agricultural Machinery

Shop

Grain Drying Equipment

Electric Vertical Batch Grain Dryer

Available for project configuration

Electric batch grain dryer with screw-driven material circulation.

Five models: 500-5,000 kg nominal load per batch.
Heaters: 18-54 kW; drive power is separate.

Confirm the permitted load and complete cycle for your material and moisture targets. Batch load is not hourly throughput.

Product category
Grain Drying Equipment
Configuration
Project-specific
01Factory direct02Technical review03Export support

Grain drying equipment / Electric heating

Electric Batch Drying for Defined Grain Loads

The ACME vertical batch grain dryer combines electric heating, a fan and screw-driven material circulation. Choose a model around your grain, starting and target moisture, and daily requirement, not just the largest load in the specification table.

500-5,000 kg per batch
Published nominal loads; confirm the loading basis for your material
18-54 kW heating
Listed heater ratings, separate from screw and fan motor ratings
Batch operation
Load, dry, check the endpoint and discharge under the agreed procedure

Technical specifications

Compare the Five Vertical Dryer Models

The load figures describe a nominal batch, not hourly throughput. Confirm the material, bulk density and permitted fill level before selecting a size.

Published model specifications. Loading conditions and supplied configuration require confirmation.
ParameterModel 500Model 1000Model 2000Model 3000Model 5000
Nominal batch load*500 kg1,000 kg2 t3 t5 t
Heating element power18 kW30 kW36 kW36 kW54 kW
Screw + fan motor ratings*3 + 0.75 kW4 + 0.75 kW5.5 + 1.5 kW7.5 + 1.5 kW11 + 2.2 kW
Listed construction material*201 stainless201 stainless201 stainless201 stainless201 stainless
Plate thickness2.0 mm2.0 mm2.0 mm2.0 mm2.5 mm
Barrel height + cone height1000 + 670 mm1220 + 920 mm1220 + 1000 mm1500 + 1500 mm1800 + 1600 mm
Listed overall size: diameter x height*1100 x 2400 mm1350 x 2900 mm1600 x 3100 mm2000 x 3850 mm2300 x 4250 mm

Load and cycle: confirm the reference material, allowable minimum and maximum fill, moisture targets and complete cycle. These specifications do not establish a drying time or daily output. Use the capacity planning method below to define your required duty.

Electrical ratings: the heater, screw and fan values are separate nameplate-style ratings, not measured energy consumption. Final electrical input, starting requirements and supply protection must be confirmed for the delivered configuration.

Construction and space: confirm which components the 201 stainless specification covers, including contact surfaces and seals. Allow additional space for loading, discharge, ventilation and maintenance beyond the listed dimensions.

How it works

How the Vertical Batch Dryer Works

  1. Load a defined batch

    Introduce the material through the loading arrangement. Match the batch to the permitted fill level and material density rather than treating the nominal kg figure as universal.

  2. Circulate the material

    The screw moves material through the vessel during operation. Circulation is part of the drying design; actual moisture uniformity and handling damage must be evaluated for the grain and settings used.

  3. Heat the air and remove moisture

    Electric heating and the fan provide the drying air. Confirm the air path, exhaust arrangement and operating temperature limits for the quoted configuration.

  4. Check the endpoint and discharge

    Use the agreed sampling and moisture-checking procedure. Include any required cooling or conditioning before transfer, then discharge and inspect for retained material before the next batch.

Structure illustration

Inside the Vertical Batch Dryer

Review the vessel, screw assembly, air-handling components and discharge arrangement. Use the illustration to discuss the configuration required for your material and site.

Vertical dryer structure illustration with labelled vessel, screw, drive, air-handling components, control box and discharge assembly
Illustrative component layout, not an assembly or installation drawing. Confirm supplied components and connections.View full-size diagram
Vessel and material circulation
The drawing identifies the cylindrical vessel, conical lower section, screw assembly and drive. Confirm the permitted fill level and arrangement for the selected model.
Heating and air-handling system
Review the shown blower, ducting and controls against the quoted electric-heating configuration. Component labels do not define the complete air or exhaust path.
Discharge, support and access
Check outlet positions, support requirements and maintenance access against the final drawing. Allow space around the machine as well as its listed footprint.

Animation and equipment reference

Material Movement and Equipment Details

Internal movement animation

Concept animation / approximately 15 secondsOpen animation

An illustrative view of material movement and airflow. The animation does not establish the final internal design, drying time, moisture uniformity or energy consumption.

Equipment reference footage

Equipment footage / approximately 61 secondsOpen equipment video

The source clip is labelled “vertical mixer” and shows equipment features. It does not verify the heated dryer configuration or a drying result. Confirm the heating, fan and control system for the quoted machine.

Material and application

Match the Dryer to Your Grain and Moisture Targets

Discuss wheat, corn or beans with the required end use and moisture conditions. An application match does not mean that different materials share the same load, temperature limit or drying cycle.

Vertical batch dryer illustration for separate grain lots

Separate grain lots

For grain arriving in individual lots, assess each material and moisture condition. Allow for sampling, unloading and the cleaning needed to maintain lot identity.

Selection inputs: lot size, moisture range and available working hours.

Vertical dryer equipment illustration for material selection

Wheat, corn and beans

Specify the grain or bean type and whether it is intended for food, feed or planting. Planting seed requires a separate quality assessment; grain drying does not establish germination performance.

Selection inputs: material, intended use, handling sensitivity and quality target.

Vertical dryer illustration for moisture adjustment before processing

Moisture adjustment before processing

Assess whether an otherwise suitable lot needs moisture reduction before storage or downstream processing. Drying should not be treated as a remedy for existing spoilage or contamination.

Selection inputs: present condition, moisture target and next process.

Your material and quality requirements
Name the grain, variety and end use. Include bulk density, foreign material, handling sensitivity and any customer quality specification available.
Starting and target moisture
Give the normal and highest expected inlet moisture, the required endpoint and measurement method. State whether percentages use wet or dry basis.
Batch size and daily requirement
Provide the usual lot size, daily wet input and working hours. Include upstream and downstream constraints rather than selecting by model name alone.
Site, electrical and cleaning conditions
Include the destination country, voltage, phase, frequency, available height, ventilation and cleaning requirements. Flag a limited supply or generator at the enquiry stage.
Request a Drying Assessment

Moisture figures not available yet? Describe the material and the result you need.

Capacity selection

Batch Grain Dryer Capacity: From a Load to a Daily Requirement

The published 500-5,000 kg figures are nominal batch loads, not kg per hour or guaranteed tonnes per day. A useful selection defines an allowable load for your material, a complete cycle and the amount that must be finished within your working window.

Three different capacity figures: wet material loaded per batch, wet material processed per day, and finished product after water removal. State which one you need. A model number or a heater rating cannot convert one into another.

1. Confirm the permitted load, not just the nominal kg

Ask for the reference material, usable loading volume, permitted fill range and loading method. Two materials with the same weight can occupy different volumes. The minimum load also matters: operating below the assessed fill range may change circulation and air distribution. Do not assume a half-full vessel retains the full-load cycle or uniformity.

Volume illustration only: 1,000 kg at 650 kg/m3 occupies about 1.54 m3; at 450 kg/m3 it occupies about 2.22 m3. These are assumed bulk densities, not ACME loading data. Confirm the usable fill volume separately; the outside diameter and height do not establish it.

2. Count the full time for one batch

  1. Load and prepareLoading, initial sampling and preparation that occupy the dryer.
  2. Heat, dry and checkDrying to the agreed moisture and quality endpoint, including required checks.
  3. Cool if required in the dryerInclude the time until the vessel is available for discharge and the next load.
  4. Unload and change overDischarge, inspection and cleaning needed before the next batch.

Complete cycle = loading + drying and checks + in-dryer cooling + discharge and changeover.

Available window = scheduled working hours minus separately allowed stops and contingency.

Complete batches = available window divided by complete cycle, rounded down to a whole number.

Daily wet input = permitted actual wet load per batch multiplied by complete batches.

This is a serial-batch planning method, starting with an empty machine and finishing each counted load within the window. Do not count a partly dried batch as completed output, or deduct the same changeover twice. A different overnight or overlapping schedule needs its own operating plan.

Cooling outside the dryer only releases the vessel sooner if the receiving bins, airflow, transfer equipment and staffing can keep up. It does not eliminate the cooling duty. University of Minnesota Extension's wheat and barley guidance explains why end use, kernel temperature and cooling affect quality. Its operating recommendations are not an ACME cycle-time specification.

3. Check a working-day example before choosing a larger model

Hypothetical arithmetic, not an ACME drying test: assume a permitted actual load of 1,000 kg, a 12-hour working window and a separate 1-hour allowance for stops and contingency. The available window is 11 hours. The times below are assumed inputs for two scenarios, not published dryer performance.

Same assumed 1,000 kg wet load; different assumed drying time
Planning itemScenario AScenario B
Loading0.25 h0.25 h
Drying and endpoint checks2.50 h3.50 h
In-dryer cooling0.50 h0.50 h
Discharge and changeover0.25 h0.25 h
Complete cycle3.50 h4.50 h
Complete batches in 11 h32
Daily wet input completed3,000 kg2,000 kg
Time left after those batches0.50 h2.00 h

For an assumed 4,000 kg/day wet-input requirement at that load, four complete batches are needed. The complete-cycle budget would be 11 / 4 = 2.75 hours. Neither scenario meets it. Ask whether a different assessed load, a longer working window or a different drying arrangement can meet the duty. Do not assume that a larger vessel or a higher temperature will solve it without a material-specific assessment.

4. Separate wet input from finished dry-product weight

For a water-removal-only balance, use moisture contents on the same wet basis: water mass divided by total wet material mass. Percentages below are entered as 20 and 14, not 0.20 and 0.14. Do not substitute dry-basis readings without conversion.

Finished mass = wet input mass x (100 - initial moisture %) / (100 - final moisture %).

Water removed = wet input mass minus finished mass, assuming no dry-matter loss.

1,000 kg from 20% to 14% wet basis
1,000 x 80 / 86 = about 930.2 kg finished material and 69.8 kg water removed. Scenario A's three batches would produce about 2,790.7 kg after water removal, not 3,000 kg of finished product.
1,000 kg from 24% to 14% wet basis
1,000 x 76 / 86 = about 883.7 kg finished material and 116.3 kg water removed. That is about 67% more water to remove, but it does not prove that drying time rises by exactly 67%.

These moisture targets are example inputs, not storage recommendations for every crop. Purdue Extension's grain-shrinkage explanation separates water loss from handling and dry-matter losses. The calculation here excludes spills, dust, screenings, retained material and other losses, so it is not a guaranteed saleable-output figure.

If your target is 4,000 kg/day of finished product at the example's 20% to 14% moisture change, the water-only wet input would be 4,000 x 86 / 80 = 4,300 kg/day. The schedule must then accommodate that wet input and any permitted final partial load. Do not plan a small final batch until its fill and cycle have been assessed.

5. Check the limiting duty and the rest of the line

Normal moisture and the wettest expected lots
Request an assessment for both, with the required endpoint and grain-quality limits. A favourable low-moisture reference run does not establish peak-season output at a higher inlet moisture.
Temperature, airflow and environment
Confirm material temperature limits, airflow and exhaust arrangements, local temperature and humidity, and the supplied controls. Models 2000 and 3000 both list 36 kW heaters; this does not establish the same cycle or a reliable time ratio.
Feeding, cooling and finished-product handling
Check loading and discharge rates, wet-material waiting capacity and any external cooling or receiving bottleneck. The dryer may finish a load faster than the rest of the line can accept it.
Power, changeover and shift availability
State supply limits, operating hours and cleaning between products. Rated kW is not measured kWh per batch, and neither is a daily-capacity guarantee. An assumed 24-hour schedule needs staffing, handling and downtime provisions.

6. Ask for a capacity assessment with a defined acceptance basis

For a capacity-critical purchase, agree a recorded trial on representative material, including the most demanding expected inlet condition. Agree which parameters must be recorded and the endpoint tolerance before the test; do not use a photograph or a mixing animation as proof of drying output.

  • Input and fill: material identity, initial condition, weighed wet load, bulk density if relevant and permitted loading level.
  • Moisture and quality: initial and final wet-basis readings, measurement method, representative sample locations and acceptable variation; assess breakage or germination separately where required.
  • Cycle record: stage start and finish times, endpoint checks, in-dryer versus external cooling, discharge and changeover.
  • Operating conditions: ambient conditions, relevant temperatures, settings and delivered equipment; note interruptions.
  • Output basis: wet input completed per shift, weighed finished material, retained material and losses, with the same boundaries as the quotation.

A single successful batch supports that recorded condition, not every material or season. Repeated runs help assess consistency. This page does not publish verified ACME batch-time or daily-throughput test records.

Vertical batch dryer range illustration
Range illustration, not proof of a customer installation or an engineering layout. Request dimensions and access requirements for the selected model.

Before installation

Power Supply, Cleaning and Installation Requirements

  • Confirm electrical requirements

    Review the heater and drive data, starting arrangement, controls and any auxiliary equipment with the supplier and a qualified electrical professional. The listed kW figures alone are not a circuit-sizing specification.

  • Allow access around the machine

    Listed heights range from 2.40 to 4.25 m. Add the loading arrangement, discharge space, service access and any required exhaust ducting; check operating loads and support requirements.

  • Define cleaning and contact materials

    The published material is 201 stainless. Confirm its component scope, seals, finish and cleaning method. Cone discharge does not establish zero residue or prevent all cross-contact between products.

  • Review heat, airflow and dust safety

    Confirm the supplied temperature controls, protection functions and exhaust arrangement. Assess grain dust and site hazards; do not assume dust collection or explosion-protected equipment is included.

Compare the process duty

Vertical Batch Dryer or Rotary Drum Dryer?

Match the drying system to material behaviour, moisture removal, lot handling and the site. Different machine shapes should not be compared using nominal capacity alone.

This vertical batch dryer
Assess an electrically heated, screw-circulated batch when separate loads and a defined batch endpoint suit the process. Confirm the cycle and available electrical supply.
KY rotary drum dryer
Review the KY rotary drum dryer if tumbling and drum-based handling may suit your material. Confirm its heat source, feed mode and process conditions before comparing output or cost.
HG rotary return-flow dryer
Review the HG rotary return-flow dryer for a different scale and drying arrangement. Compare the complete heating, handling and installation scope.
Compare equivalent conditions
Use the same grain, moisture targets, output basis and quality criteria. Separate heating energy from motor power and include loading, cooling and discharge where relevant.

Buyer questions

Vertical Batch Grain Dryer Questions

Is 500 kg the capacity per batch or per hour?

It is the published nominal load per batch, not kg/h. Confirm the reference material and permitted fill conditions. Hourly or daily output also requires the complete cycle time and must use a clear wet-input or dry-output basis.

How long does one complete batch take?

There is no universal time for all grains and moisture conditions. An assessment needs the material, actual load, inlet and target moisture, temperature limits and environment. Include loading, endpoint checks, any required cooling, unloading and changeover.

Why do Models 2000 and 3000 list the same heater power?

Both published configurations list 36 kW heating. The nominal loads differ, but that alone cannot establish the difference in drying time. Compare the two under the same material and moisture conditions, with their airflow, fill level and quality requirements defined.

Is this electrically heated or only electrically driven?

This range lists electric heating elements as well as screw and fan motors. When comparing another dryer, check whether its electric rating covers just the drives while heat comes from a separate burner or furnace.

How much electricity will one batch use?

Energy use must be measured or estimated for a defined cycle and operating conditions. Rated kW is not kWh per batch. Agree whether the measurement includes external handling, ventilation or cooling equipment before using it to compare costs.

Can it dry wheat, corn and beans?

These are applications to discuss with ACME. Provide the particular material, starting and target moisture, load and intended use. Do not apply one grain's operating settings or capacity assessment to another without review.

Can I use it for planting seed?

Seed suitability needs a separate assessment of temperature exposure, mechanical handling and germination quality. Ordinary grain drying experience does not demonstrate retained germination. Agree an appropriate recorded trial before relying on a seed-drying claim.

What does the 201 stainless specification cover?

It is the material listed in the published table, not a certification of the whole machine for every product. Confirm the barrel, screw, discharge surfaces, seals and finish individually, together with cleaning compatibility and documentation required by your buyer.

How do I know when the batch is dry enough?

Use a suitable moisture-measurement method and an agreed sampling procedure, including checks for variation across the batch. Confirm the delivered monitoring and control functions; an online moisture sensor or automatic endpoint control should not be assumed.

Is cooling included in the drying cycle?

Confirm whether cooling or conditioning is needed for the next process and where it will take place. If it uses separate equipment, include that equipment and its timing in the project assessment. A hot discharge is not automatically ready for storage.

Can different products be dried without mixing?

Batch operation allows separate loads, but does not by itself eliminate retained material. Inspect the screw, cone, outlets and contact surfaces, and agree a cleaning and changeover procedure suited to your products and cross-contact requirements.

What should I include in a quotation request?

Start with the grain, inlet and target moisture if known, daily requirement, installation country and contact details. Add the intended use, electrical supply and space constraints. Ask for a clear supply scope, selection assumptions and any trial needed to confirm performance.

Does a low-moisture trial prove peak-season drying capacity?

No. A recorded run supports its stated material, actual load, inlet moisture, target moisture, operating settings and environment. Wetter incoming material can require more water removal, but the additional time cannot be inferred from that ratio alone. Assess the most demanding expected inlet condition and the complete daily schedule before relying on a peak-season output figure.

Can I use a large model for a very small batch?

Not without confirming the permitted minimum fill and operating procedure. Circulation, airflow and heat distribution can change with load. Ask the supplier to assess your smallest routine lot as well as your peak requirement; do not assume a partial load dries proportionally faster.

Is the tonnes-per-day figure wet grain or finished dry product?

It must be stated explicitly. Wet input completed in a day and product remaining after water removal are different weights. For a water-only balance, finished mass equals wet mass multiplied by (100 minus initial wet-basis moisture %) and divided by (100 minus final wet-basis moisture %). Additional losses require separate accounting.

Can I move cooling to another bin to increase output?

Only after assessing the complete arrangement. External cooling may release the dryer sooner, but requires suitable receiving capacity, airflow, transfer equipment and an agreed grain-quality procedure. Its timing and costs remain part of the project, and hot grain is not automatically ready for storage.

Plan your drying duty

Tell Us What Must Be Finished in Your Working Day

Send the drying duty, not just a model number. Request a proposed load, cycle assumptions, supply scope and any trial needed before a daily-capacity commitment.

  • Material, end use and smallest usual lot
  • Normal and highest expected inlet moisture; target moisture and measurement basis
  • Required kg or tonnes per day, explicitly wet input or finished output
  • Operating hours, cooling location, cleaning and changeover needs
  • Country, electrical supply and space or handling limits

Start with the information you have

Missing moisture readings or a cycle time? Say what is unknown. Send the material, daily requirement, available hours and destination first; the loading and performance conditions still need assessment.