Process & Quality
Grain Cleaning Equipment
Configuration is selected according to your raw material, target product, required capacity and site conditions.
Cleaning and stone removal for small mills
Small stones, grit, dust and light husk arrive with the wheat and go straight for your rollers if nothing takes them out.
The integrated fan and cyclone provide the machine's aspiration arrangement. Confirm the feed connection, collected-dust discharge and site air-handling requirements in the supply scope.
Airflow and deck motion separate denser stones from grain. Keep grain and reject outlets separate, and check both streams before sending material onward.
Inside the machine
A combined cleaner uses different separation steps for different impurities. The illustration below identifies the feed and lifting connection, screening area, de-stoning deck, fan and receiving hopper.
Principle and workshop footage
The animation explains the process. The workshop video shows a combined cleaner handling material. Use them to discuss the arrangement; accept throughput and cleaning results only against an agreed material test.
Simplified material-flow reference. The animation is not an assembly instruction or a measured removal-rate test.
Feed enters the screening area. Size separation removes oversize and undersize material. On the de-stoning deck, upward air and deck motion separate denser stones from grain. Aspiration carries light material toward the dust collection path; grain and rejects leave through different outlets.
Actual equipment and material views. The recording does not provide a timed, weighed capacity test or a quantified stone-removal result.
The footage follows the machine, feed connection and receiving points, with close-ups of the material during operation. Compare the collection points with the layout agreed for your installation and check grain loss in reject streams during commissioning.
How it works
The QSX combines grain cleaning and de-stoning in a compact arrangement with an integrated fan and cyclone. Screening, aspiration and density separation perform different jobs; none replaces a complete agreed cleaning specification.
The suction-assisted arrangement draws grain through its feed connection. Confirm the receiving hopper, lifting pipe, feed distance and incoming flow for the actual installation.
Aspiration carries dust and light husk toward the cyclone. Confirm how separated dust and exhaust air are handled; an integrated cyclone does not settle every site dust-control requirement.
Upward air loosens the grain bed while denser stones remain in closer contact with the moving deck. The two fractions follow different paths. Feed distribution, airflow and deck settings affect the result.
Inspect the grain outlet for remaining impurities and the reject outlets for lost usable grain. Release material onward only when it meets the cleaning standard agreed for your line.
Before we choose a model
This machine covers 500 to 800 kg an hour, so the first thing to settle is whether that matches the mill you are building.
Where it sits in the line

Compare the catalog 500 or 800 kg/h with the peak flow through the cleaner, not just the mill's daily tonnage. Larger hourly flows need a separately sized cleaning and de-stoning arrangement.

The fan and cyclone are part of the catalog arrangement. Confirm collection, exhaust and site connections before treating the installation as complete.

Stones are what break rollers and screens. Taking them out at the last step before milling is where it counts most.
Technical specifications
Note the unit: this machine is rated in kilograms per hour, not tonnes. It is a small-mill machine, and the figures below say so plainly.
| Parameter | QSX30 | QSX40 |
|---|---|---|
| Capacity | 500 kg/h | 800 kg/h |
| Motor power | 3 kW | 4 kW |
| Main shaft speed | 1,440 r/min | 1,440 r/min |
| Installed size (L x W x H) | 1650 x 940 x 2800 mm | 1650 x 940 x 2800 mm |
| Crated size for shipping | 1550 x 950 x 1350 mm | 1550 x 950 x 1350 mm |
| Weight | 260 kg | 350 kg |
Read the two size rows carefully: the crate is 1,350 mm tall, but the machine stands 2,800 mm once the cyclone is fitted. Plan your building around the installed height, not the shipping crate. Both models occupy the same floor space; the difference between them is capacity, motor size and build weight.
Choosing a model
500 or 800 kg an hour. If your line needs tonnes per hour, this is the wrong machine and we will point you to the right one rather than oversell this.
De-stoning works on weight difference, so the setting depends on your grain and how much grit comes with it. Send a sample or photos.
The catalog installed height is 2,800 mm, not the 1,350 mm crate height. Allow additional access and connection space according to the approved layout.
Before acceptance
A useful trial records more than how clean one bowl looks. Compare representative feed and all discharge streams under the same recorded settings.
Record the crop, moisture if known, incoming impurity mix and required kg/h. Agree the screen arrangement and collect a representative feed sample, not only a handful selected for the camera.
Use a timed, weighed run. Keep grain, stones, screen rejects and collected light material separate. Check remaining impurities in grain and usable grain in each reject stream; do not report only a removal percentage without its calculation basis.
Note feed rate, screen openings and air/deck settings with photographs of the outlets. Compare results with the agreed acceptance limits. No removal efficiency or grain-loss guarantee is implied by the videos on this page.

Before we quote
Common questions
Two things in one unit. Air takes out dust and light husk and collects it in the cyclone on top. The de-stoning deck separates stones and grit from the grain by weight and sends them out a separate outlet. Inspect the grain and reject streams against an agreed acceptance standard before releasing material to the mill.
The catalog QSX arrangement includes its own fan and cyclone. Confirm the complete equipment list, feed pipework, collected-dust handling and exhaust connections in your quotation. Additional site measures may be needed; the integrated cyclone alone does not define a complete dust-control system.
Use the catalog hourly capacities of 500 kg/h for QSX30 and 800 kg/h for QSX40 as the starting comparison. For example, 800 kg/h multiplied by 8 productive hours is 6.4 tonnes, not a guaranteed shift output. A 20 t/day line over 24 hours requires more than 833 kg/h before downtime, so QSX40 should not be assumed sufficient. Confirm peak flow, material and the full cleaning line.
Capacity and build. The QSX40 handles 800 kg/h against 500 kg/h, uses a 4 kW motor against 3 kW, and weighs 350 kg against 260 kg. They occupy the same floor space and the same installed height.
Because the cyclone is fitted during installation, not shipped standing up. Buyers who size their building from the crate dimensions get caught out by this, so plan around 2,800 mm.
De-stoning works on the weight difference between grain and stone, so the setting depends on the crop. Tell us what you plan to run and we will confirm whether the machine suits it and how it should be set.
The grain, your hourly flow in kilograms, photos or a sample showing the stones and dust, your ceiling height, your country and voltage, and what feeds the machine and what it feeds into.
We will confirm whether the QSX suits your flow, which model fits, and how it should connect at both ends.